9 research outputs found

    EXPERIMENTAL-COMPUTATIONAL ANALYSIS OF VIGILANCE DYNAMICS FOR APPLICATIONS IN SLEEP AND EPILEPSY

    Get PDF
    Epilepsy is a neurological disorder characterized by recurrent seizures. Sleep problems can cooccur with epilepsy, and adversely affect seizure diagnosis and treatment. In fact, the relationship between sleep and seizures in individuals with epilepsy is a complex one. Seizures disturb sleep and sleep deprivation aggravates seizures. Antiepileptic drugs may also impair sleep quality at the cost of controlling seizures. In general, particular vigilance states may inhibit or facilitate seizure generation, and changes in vigilance state can affect the predictability of seizures. A clear understanding of sleep-seizure interactions will therefore benefit epilepsy care providers and improve quality of life in patients. Notable progress in neuroscience research—and particularly sleep and epilepsy—has been achieved through experimentation on animals. Experimental models of epilepsy provide us with the opportunity to explore or even manipulate the sleep-seizure relationship in order to decipher different aspects of their interactions. Important in this process is the development of techniques for modeling and tracking sleep dynamics using electrophysiological measurements. In this dissertation experimental and computational approaches are proposed for modeling vigilance dynamics and their utility demonstrated in nonepileptic control mice. The general framework of hidden Markov models is used to automatically model and track sleep state and dynamics from electrophysiological as well as novel motion measurements. In addition, a closed-loop sensory stimulation technique is proposed that, in conjunction with this model, provides the means to concurrently track and modulate 3 vigilance dynamics in animals. The feasibility of the proposed techniques for modeling and altering sleep are demonstrated for experimental applications related to epilepsy. Finally, preliminary data from a mouse model of temporal lobe epilepsy are employed to suggest applications of these techniques and directions for future research. The methodologies developed here have clear implications the design of intelligent neuromodulation strategies for clinical epilepsy therapy

    \u3cem\u3eSegWay\u3c/em\u3e: A Simple Framework for Unsupervised Sleep Segmentation in Experimental EEG Recordings

    Get PDF
    Sleep analysis in animal models typically involves recording an electroencephalogram (EEG) and electromyogram (EMG) and scoring vigilance state in brief epochs of data as Wake, REM (rapid eye movement sleep) or NREM (non-REM) either manually or using a computer algorithm. Computerized methods usually estimate features from each epoch like the spectral power associated with distinctive cortical rhythms and dissect the feature space into regions associated with different states by applying thresholds, or by using supervised/unsupervised statistical classifiers; but there are some factors to consider when using them: Most classifiers require scored sample data, elaborate heuristics or computational steps not easily reproduced by the average sleep researcher, who is the targeted end user. Even when prediction is reasonably accurate, small errors can lead to large discrepancies in estimates of important sleep metrics such as the number of bouts or their duration. As we show here, besides partitioning the feature space by vigilance state, modeling transitions between the states can give more accurate scores and metrics. An unsupervised sleep segmentation framework, “SegWay”, is demonstrated by applying the algorithm step-by-step to unlabeled EEG recordings in mice. The accuracy of sleep scoring and estimation of sleep metrics is validated against manual scores

    Credibility Evidence for Computational Patient Models Used in the Development of Physiological Closed-Loop Controlled Devices for Critical Care Medicine

    Get PDF
    Physiological closed-loop controlled medical devices automatically adjust therapy delivered to a patient to adjust a measured physiological variable. In critical care scenarios, these types of devices could automate, for example, fluid resuscitation, drug delivery, mechanical ventilation, and/or anesthesia and sedation. Evidence from simulations using computational models of physiological systems can play a crucial role in the development of physiological closed-loop controlled devices; but the utility of this evidence will depend on the credibility of the computational model used. Computational models of physiological systems can be complex with numerous non-linearities, time-varying properties, and unknown parameters, which leads to challenges in model assessment. Given the wide range of potential uses of computational patient models in the design and evaluation of physiological closed-loop controlled systems, and the varying risks associated with the diverse uses, the specific model as well as the necessary evidence to make a model credible for a use case may vary. In this review, we examine the various uses of computational patient models in the design and evaluation of critical care physiological closed-loop controlled systems (e.g., hemodynamic stability, mechanical ventilation, anesthetic delivery) as well as the types of evidence (e.g., verification, validation, and uncertainty quantification activities) presented to support the model for that use. We then examine and discuss how a credibility assessment framework (American Society of Mechanical Engineers Verification and Validation Subcommittee, V&V 40 Verification and Validation in Computational Modeling of Medical Devices) for medical devices can be applied to computational patient models used to test physiological closed-loop controlled systems

    Multivariate physiological recordings in an experimental hemorrhage model

    No full text
    In this paper we describe a data set of multivariate physiological measurements recorded from conscious sheep (N = 8; 37.4 ± 1.1 kg) during hemorrhage. Hemorrhage was experimentally induced in each animal by withdrawing blood from a femoral artery at two different rates (fast: 1.25 mL/kg/min; and slow: 0.25 mL/kg/min). Data, including physiological waveforms and continuous/intermittent measurements, were transformed to digital file formats (European Data Format [EDF] for waveforms and Comma-Separated Values [CSV] for continuous and intermittent measurements) as a comprehensive data set and stored and publicly shared here (Appendix A). The data set comprises experimental information (e.g., hemorrhage rate, animal weight, event times), physiological waveforms (arterial and central venous blood pressure, electrocardiogram), time-series records of non-invasive physiological measurements (SpO2, tissue oximetry), intermittent arterial and venous blood gas analyses (e.g., hemoglobin, lactate, SaO2, SvO2) and intermittent thermodilution cardiac output measurements. A detailed explanation of the hemodynamic and pulmonary changes during hemorrhage is available in a previous publication (Scully et al., 2016) [1]
    corecore